Center for Computer-Integrated Surgical Systems & Technology (CISST)MRI-Guided Needle Placement with Augmented Reality GuidanceResearchers at the Computer-Integrated Surgical Systems and Technology (CISST) Engineering Research Center, in collaboration with clinicians at the Johns Hopkins Hospital and funded by Siemens, have developed a robust and inexpensive augmented reality apparatus to aid image-guided needle placement on conventional closed high-field magnetic resonance imaging (MRI) scanners. MRI has an unmatched potential for guiding, monitoring, and controlling minimally invasive percutaneous (needle-based) interventions. At the same time, MRI presents formidable challenges. The high magnetic field precludes conventional materials and devices, and access to the patient inside the magnet is severely limited. We have been developing robots for in-scanner use, but they are unlikely to be clinically practical in the near future. Thus, CISST researchers also focus on augmented reality solutions that can become available in the close future and can be disseminated across a wide range of care facilities with minimal cost and overhead. A wide variety of virtual reality methods have been investigated by other
groups, but all prior solutions require painstaking calibration, and spatial
tracking of all actors and components, resulting in complex, cumbersome,
and invariably expensive systems. The device developed at the CISST ERC
consists of a flat LCD display and a half mirror, mounted in the mouth
of the MR magnet (Figure 1) When the practitioner looks at the patient
through the mirror, the MR image appears to be floating inside the patient
with correct size and position, thereby providing the physician with tomographic
vision to guide the needle placement. The physician inserts the needle
following the optimal path identified in the MR image and reflected in
the mirror. The system promises to increase needle placement accuracy
and reduces patient discomfort and procedure time by eliminating faulty
insertion attempts. Extensive cadaver studies have been conducted for
several applications with a clinically applicable device. Drs. John Carrino,
Laura Fayad, and James Zinreich at the Johns Hopkins Medical Institutions
will be introducing the device to clinical trials in musculoskeletal biopsies
and joint arthrography (Figure 2.) To learn more about this topic:
|
|
|
The MR Image Overlay device (upper) and
Human cadaver study in joint arthrography: Learn More |
|
|
Home | All Achievements (listed by center) | Research Advances | Technology Transfer Achievements Education & Outreach Achievements | Related Information & Links | In the Media | Featured Achievement | Site Map Engineering Education & Centers Home | ERC Program Home | ERC Association Home Contact the ERC Achievements Showcase Webmaster. Last modified: April 3, 2007 |
|